How Many Questions Of DES-4122 Sample Question

Guaranteed of DES-4122 test question materials and free download for EMC certification for client, Real Success Guaranteed with Updated DES-4122 pdf dumps vce Materials. 100% PASS Specialist - Implementation Engineer PowerEdge Version 2.0 exam Today!

Also have DES-4122 free dumps questions for you:

NEW QUESTION 1

A technician working with a Dell EMC PowerEdge 1 take corrective action?

  • A. Check the System Event Log Check PSU LED Reseat the PSU
  • B. Check the System Event Log Check PSU LEDDo a virtual reseat of the iDRAC
  • C. Check the LCC Log Check PSU LED Reseat the CPU
  • D. Check the LCC Log Check PSU LED Reseat the PSU

Answer: B

NEW QUESTION 2

For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.
When you have finished using the simulator, click Next.
DES-4122 dumps exhibit


Solution:
Send us your suggestion for this simulation task.

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 3

A technician working with a Dell EMC PowerEdge 14G server observes the PCIe indicator turn solid amber What should they do to take corrective action upon checking the System Event log?
A)
DES-4122 dumps exhibit
B)
DES-4122 dumps exhibit
C)
DES-4122 dumps exhibit
D)
DES-4122 dumps exhibit

  • A. Option A
  • B. Option B
  • C. Option C
  • D. Option D

Answer: C

NEW QUESTION 4

What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

  • A. SupportAssist Enterprise
  • B. iSM
  • C. OpenManage Essentials
  • D. iDRAC9

Answer: C

NEW QUESTION 5

What is a valid password option available from the iDRAC9 Unique ID feature?

  • A. Encryption Default
  • B. Secure Default
  • C. Legacy Generated
  • D. Randomly Generated

Answer: D

NEW QUESTION 6

Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?

  • A. NDC
  • B. OCP
  • C. PCIe
  • D. FPGA

Answer: C

NEW QUESTION 7

An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment
The inventory consists of:
DES-4122 dumps exhibit
The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb
What additional component(s) is needed for this configuration?

  • A. Hot-plug power supply, 750 W - qty 1
  • B. Hot-plug power supply, 1100W - qty 1
  • C. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2
  • D. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2

Answer: D

NEW QUESTION 8

What is required to use the iSM Automatic System Recovery feature?

  • A. Server Administrator installed
  • B. OS watchdog timer disabled
  • C. Server Administrator not installed
  • D. OS watchdog timer enabled

Answer: B

NEW QUESTION 9

A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.
DES-4122 dumps exhibit


Solution:
Send us your suggestion for this simulation task.

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 10

A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?

  • A. Both the iDRAC and the LCC can be rolled back
  • B. The LCC can be rolled back; the iDRAC cannot be rolled back
  • C. The iDRAC can be rolled back; the LCC cannot be rolled back
  • D. The iDRAC cannot be rolled back and the LCC cannot be rolled back

Answer: B

NEW QUESTION 11

A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?

  • A. Use a configuration option to convert an NVMe drive to a virtual vFlash
  • B. Use a configuration option to convert BOSS to a virtual vFlash
  • C. Reuse an existing vFlash SD card from a 14G server
  • D. Reuse an existing vFlash SD card from either a 13G or 14G server

Answer: C

NEW QUESTION 12

Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.
DES-4122 dumps exhibit


Solution:
DES-4122 dumps exhibit

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 13

What is required for iDRAC Direct 2.0 to connect with IDRAC9 interfaces such as RACADM and WSMAN?

  • A. Wi-Fi connection
  • B. NFC connection
  • C. Ethernet cable
  • D. Micro-AB USB

Answer: D

NEW QUESTION 14

A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?

  • A. System Profile
  • B. Virtualization Technology
  • C. HyperThreading
  • D. Number of Cores per Processor

Answer: A

NEW QUESTION 15

For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.
DES-4122 dumps exhibit


Solution:
Send us your suggestion for this simulation task.

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 16

What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?

  • A. NVDIMMs cannot be mixed with RDlMMs
  • B. NVDIMMs can be mixed only with LRDIMMs
  • C. RDlMMs can be mixed only with NVDIMMs
  • D. LRDIMMs can be mixed only with RDlMMs

Answer: B

NEW QUESTION 17

An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?

  • A. Confirm the System Input Power CAP is not set to Low
  • B. Set the PSU AC redundancy to 1+1
  • C. Set the PSU AC redundancy to 1+0
  • D. Verify the new PSU is the same type and wattage rating

Answer: D

NEW QUESTION 18
......

100% Valid and Newest Version DES-4122 Questions & Answers shared by Certleader, Get Full Dumps HERE: https://www.certleader.com/DES-4122-dumps.html (New 60 Q&As)