Renovate NS0-520 Free Dumps For NetApp Certified Implementation Engineer - SAN. ONTAP Certification
It is impossible to pass Network-Appliance NS0-520 exam without any help in the short term. Come to Certleader soon and find the most advanced, correct and guaranteed Network-Appliance NS0-520 practice questions. You will get a surprising result by our Refresh NetApp Certified Implementation Engineer - SAN. ONTAP practice guides.
Network-Appliance NS0-520 Free Dumps Questions Online, Read and Test Now.
NEW QUESTION 1
Referring to the exhibit, which security feature would guarantee that the host A system that is mapped to LUN XYZ on the NetApp storage system is the only host that access the LUN?
- A. igroup setup with the IQN of the ISCSi software initiator on Host A.
- B. CHAP configured on HOST A and the NetApp Storage System
- C. igroup setup with no IQNs
- D. IPsec configured on both host A and the NetApp Storage System
Answer: B
Explanation:
Graphical user interface, text, application, email Description automatically generated
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-3FC8A37A-FFC
NEW QUESTION 2
You are configuring FC ports on front-end SAN switches for a 4-node Metrocluster configuration across two data centers. You need to ensure that each data center serves FC LUNs when an FC port goes
offline in one data center. In this scenario, which front end switch setting must be modified to avoid overlap when a new port comes online?
- A. NPIV enabled
- B. NPIV reject
- C. WWPN reject
- D. ANA mapped
- E. WWNN reject
Answer: A
Explanation:
Best practice: NPIV is required for FC LIFs to operate correctly. Before creating FC LIFs, make sure that any fabrics attached to an ONTAP system have NPIV enabled.
You can find more information on this link: https://www.netapp.com/pdf.html?item=/media/10680-tr4080pdf.pdf
NEW QUESTION 3
Referring to the exhibit, which container gains space savings from deduplication, compression and compaction?
- A. the aggregate
- B. the qtree
- C. the volume
- D. the LUN
Answer: C
NEW QUESTION 4
A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 that is running ISCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.
- A. Volume move
- B. Volume rehost
- C. Volume reallocation
- D. Aggregate reallocation
Answer: B
Explanation:
Moving a Volume will only work if you are doing it within the same SVM
Volume Reallocation is used when you add new disks to an aggregate and you need to redistribute the data Aggregate Reallocation can be used only when you are moving data from an AFF filer to another AFF filer Rehosting a volume from one SVM to another SVM
Volume rehost enables you to reassign NAS or SAN volumes from one storage virtual machine (SVM, formerly known as Vserver) to another SVM without requiring a SnapMirror copy. The volume rehost procedures depend upon the protocol type and the volume type. Volume rehost is a disruptive operation for data access and volume management.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-vsmg%2FGUID-84308166-6872
NEW QUESTION 5
You want to move a SAN LIF and preserve its configuration information and avoid rezoning the switch fabric. In this scenario, which two steps must be performed to fulfill this goal? (Choose two)
- A. Move the SAN LIF to another node in a cluster on a different storage virtual machine (SVMs)
- B. Keep the SAN LIF online before it is moved
- C. Take the SAN LIF offline before it is moved
- D. Move the SAN LIF to another node in a cluster on existing storage virtual machine (SVMs)
Answer: CD
Explanation:
Moving SAN LIFs
If a node needs to be taken offline, you can move a SAN LIF to preserve its configuration information, such as its WWPN, and avoid rezoning the switch fabric. Because a SAN LIF must be taken offline
before it is moved, host traffic must rely on host multipathing software to provide nondisruptive access to the LUN. You can move SAN LIFs to any node in a cluster, but you cannot move the SAN LIFs
between storage virtual machines (SVMs). Yoy can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-09F5C2A3-FA6
NEW QUESTION 6
When running diagnostic tests after an initial installation of a NetApp FAS3000 storage system, which command is used to run a comprehensive set of diagnostic tests on the entire system?
- A. all
- B. comprehensive
- C. full
- D. stress
Answer: A
NEW QUESTION 7
An administrator is planning a hardware refresh and data migration from a Data ONTAP 7.3 system to new AFF A3-00 cluster that is using ONTAP 9.0. The Mode system only serves FC LUNs to a Windows 2012Rs server cluster that needs to remain connected after migration Referring to the scenario, which method would be used for the LUN migration.
- A. Unified Host Utility Kit
- B. 7-Mode Transition Tool (7MIT)
- C. Foreign LUN import (FLI)
- D. Oncommand system Manager
Answer: B
NEW QUESTION 8
You create a new iSCSI SVM and secure iSCSI sessions by using both Challenge-Handshake Authentication Protocol (CHAP) and iSCSI Access Control Lists (ACL).
In this scenario, in which two ways are you securing your iSCSI implementation? (Choose two.)
- A. CHAP creates a hash value for the username and shared secret.
- B. iSCSI ACLs are applied to the initiator configuration to provide an IP address of the targets.
- C. CHAP encrypts all iSCSI session I/O.
- D. iSCSI ACLs are applied to the target configuration to provide an IP address of the initiators.
Answer: AD
NEW QUESTION 9
When planning out a new FC SAN implementation for a AFF cluster, which two variables should be considered for a highly-available, resilient solution? (Choose two.)
- A. Length of LC/LC optic cables
- B. Multiple disk shelves
- C. Multiple PDUs connected to separate circuits
- D. Data-fabric zones using multiple switches
Answer: CD
NEW QUESTION 10
You want to create an additional SVM from the System Manager GUI to serve data only using block-based protocols. You know the SVM name, the aggregate containing the root volume, and the required protocols.
What other information is required to successfully create this SVM?
- A. name servers
- B. SVM Management LIF network details
- C. search domains
- D. root volume security style
Answer: D
NEW QUESTION 11
A customer is required to encrypt iSCSI traffic across their public network. In this scenario, which method will accomplish this task?
- A. dot1q
- B. IPsec
- C. NVMe
- D. CHAP
Answer: B
NEW QUESTION 12
An administrator wants to implement FCoE for connectivity of an AFF A200 using VLAN 3011 for fabric traffic across VSAN 11. When configuring the Nexus switches for FCoE connectivity, which two actions are required? (Choose two.)
- A. Create a new virtual FC interface and bind the physical interface to it.
- B. Add the virtual interface to the VSAN.
- C. Create a port channel and add all of the physical network ports that will have FCoE LIFs.
- D. Add the adapter MAC address to the network port configuration where the node is connected.
Answer: BC
NEW QUESTION 13
A customer experiences intermittent connectivity problems between an ESXi server and FC LUNs in an SVM. The customer has examined the nodes hosting the LUNs and both the disk and CPU performance are below 50% utilization. The customer examined the switch ports connected to the storage array, and they ate also below 50% utilization.
Which two steps would you perform next in this scenario? (Choose two.)
- A. Verify that the host is using SnapDrive.
- B. Verify that the host Ethernet interfaces are using jumbo frames.
- C. Verify that the host recommended settings were applied by Virtual Storage Console.
- D. Verify that the HBA queue depth is set properly.
Answer: CD
NEW QUESTION 14
A customer has multiple host applications that require FC block storage. You need to gather and validate the customer’s requirements for a supported NetApp solution.
Which two tools would be used to accomplish this task? (Choose two.)
- A. Interoperability Matrix Tool (IMT)
- B. OneCollect
- C. Config Advisor
- D. Hardware Universe (HWU)
Answer: AD
Explanation:
Reference: https://www.netapp.com/us/technology/interop.aspx
NEW QUESTION 15
Exhibit.
You want to map a LUN to a server.
To which SAN object is the highlighted value in the exhibit added?
- A. LUN
- B. fabric zone
- C. FlexClone
- D. igroup
Answer: D
NEW QUESTION 16
You will be purchasing two high availability NetApp AFF A700s systems. You want to set up a 4-node cluster. Which switch would you use for the cluster interconnect switches?
- A. NetApp CN1610
- B. Cisco Nexus 3132Q-V
- C. Cisco Nexus 5548UP
- D. Cisco Nexus 5020
Answer: B
NEW QUESTION 17
......
Thanks for reading the newest NS0-520 exam dumps! We recommend you to try the PREMIUM Dumpscollection.com NS0-520 dumps in VCE and PDF here: https://www.dumpscollection.net/dumps/NS0-520/ (234 Q&As Dumps)