Renew NetApp Certified Support Engineer - ONTAP Specialist NS0-592 Practice Question

Want to know Ucertify NS0-592 Exam practice test features? Want to lear more about Network-Appliance NetApp Certified Support Engineer - ONTAP Specialist certification experience? Study Precise Network-Appliance NS0-592 answers to Replace NS0-592 questions at Ucertify. Gat a success with an absolute guarantee to pass Network-Appliance NS0-592 (NetApp Certified Support Engineer - ONTAP Specialist) test on your first attempt.

Online NS0-592 free questions and answers of New Version:

NEW QUESTION 1
Click the exhibit button.
NS0-592 dumps exhibit
NS0-592 dumps exhibit
A customer reports that storage latency has recently increased substantially. No changes have been introduced, and the traffic did not change.
Referring to the output shown in the exhibit, which corrective step should be taken?

  • A. Add more spindles.
  • B. Throttle the client traffic.
  • C. Perform the volume reallocation.
  • D. Move some volumes off the affected aggregate.

Answer: B

NEW QUESTION 2
Click the exhibit button.
NS0-592 dumps exhibit
A customer’s system reported several errors. There was no disruption, but the customer is concerned about the system’s health.
Referring to the exhibit, which statement is true?

  • A. One of the switches has failed.
  • B. One of the IOM modules on shelf 20 has failed.
  • C. Storage redundancy is degraded.
  • D. Port 1D on the system has failed.

Answer: C

NEW QUESTION 3
Click the exhibit button.
NS0-592 dumps exhibit
A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.
Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)

  • A. Review the LIF configuration on the cluster.
  • B. Review the driver version on the server.
  • C. Review that the host side FC link ports are enabled.
  • D. Review the igroup configuration on the cluster.

Answer: AB

NEW QUESTION 4
Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.
In this scenario, what is the reason for the behavior?

  • A. The volume move command uses the HA iWarp interconnect, not the client access switches.
  • B. The volume move command uses copy offload protocol, so it does not show up when monitored.
  • C. The volume move command uses the intercluster LIFs, not the data LIFs.
  • D. The volume move command uses the cluster interconnect switches, not the client access switches.

Answer: B

NEW QUESTION 5
Click the exhibit button.
NS0-592 dumps exhibit
A customer has the ns-switch shown in the exhibit.
Which two statements are true in this scenario? (Choose two.)

  • A. User names not present in the local database are looked up in LDAP.
  • B. User mapping decisions are always based on the LDAP configuration.
  • C. Host names are always resolved using the configured DNS server.
  • D. Groups can be looked up both in the local database and in LDAP.

Answer: CD

NEW QUESTION 6
A customer reports that one their SVMs has two default gateways. The customer wants to know whether this behavior is expected or if one of gateways should be deleted.
In this scenario, what do you tell the customer?

  • A. The configuration is acceptable if the customer configures different metrics on all defaults routes.
  • B. The configuration is acceptable only if both default gateways are in the same subnet.
  • C. This situation is a misconfiguration, and the customer should delete one of the default gateways because there can be only gateway for each SVM.
  • D. The configuration is acceptabl
  • E. The customer can achieve load balancing between the default gateways by setting the same metric on all default routes.

Answer: A

NEW QUESTION 7
Your customer states that the storage efficiency on their FAS 8200 is far below what they had expected for a VMware NFS datastore. They enabled deduplication three days ago. The job ran every night for only 10-20 minutes, and the space savings now is less than 5%.
What is causing the space savings to be so low?

  • A. They have enabled aggregate-level inline data compaction, so the savings are at the aggregate level.
  • B. They have enabled aggregate-level inline deduplication, so the savings are at the aggregate level.
  • C. They have not enabled volume-level compression.
  • D. They have not run a baseline deduplication to scan old data.

Answer: C

NEW QUESTION 8
A reboot was performed by a watchdog reset on the node. In this scenario, which statement is true?

  • A. The service processor no longer responds.
  • B. In case of an L1 watchdog event, determine whether a panic message was recorded.
  • C. In case of an L2 watchdog event, determine whether a core was dumped.
  • D. The wafl_check command should be executed.

Answer: A

NEW QUESTION 9
Which statement is correct about the wafliron command?

  • A. The wafliron command is used to correct parity inconsistencies.
  • B. The wafliron command is used to correct inconsistent WAFL metadata.
  • C. The wafliron command is used to correct WAFL i2p inconsistencies.
  • D. The wafliron command is used to correct inconsistent user data blocks.

Answer: B

NEW QUESTION 10
A customer is attempting to move from NFSv3 to NFSv4.x and reports that all attempts to mount using NFSv3 continue to be successful, however, all of their NFSv4.x mount attempts fail with an “access denied” error.
Which two statements would cause this error? (Choose two.)

  • A. The NFS server does not have NFSv4 enabled.
  • B. The SVM’s root volume allows execute access for all users.
  • C. The export policy applied to the data volume does not allow clients to access it using NFSv4.
  • D. The export policy applied to the SVM’s root volume does not allow the NFSv4 clients to access it.

Answer: BC

NEW QUESTION 11
Click the exhibit button.
NS0-592 dumps exhibit
Your customer reports that their FAS2554A system reports multi-path HA when running the sysconfig command. However, Config Advisor reports an error about incorrect cabling.
What are the two reasons for the messages? (Choose two.)

  • A. Shelves 10 and 20 have different IOM modules and must be in separate stacks.
  • B. The FAS2554 system is cabled incorrectly to shelf ID 20.
  • C. The DS2246 shelf is wrong; the shelf ID must be 11.
  • D. Disk shelves 10 and 20 are cabled incorrectly to each other.

Answer: BD

NEW QUESTION 12
Click the exhibit button.
NS0-592 dumps exhibit
A customer is reporting that numbers in the statistics volume show command output appear to be incorrect. Referring to the exhibit, which statement is correct?

  • A. The problem is due to a difference in operation size.
  • B. Perfstat should be used to explain the behavior.
  • C. There are operation types that are not listed in the output.
  • D. A case with NetApp should be raised to find the root cause.

Answer: A

NEW QUESTION 13
You want to determine which SMB versions that a CIFS server can use when communicating with external servers.
Which two CIFS server settings should be reviewed to accomplish this task? (Choose two.)

  • A. smb2-enabled
  • B. smb1-enabled-for-dc-connections
  • C. smb2-enabled-for-dc-conections
  • D. smb1-enabled

Answer: CD

NEW QUESTION 14
In a 4-node MetroCluster cluster, both clusters are alerting that the connection to an ATTO bridge is lost.
Which three components should be verified to determine what is causing this problem? (Choose three.)

  • A. the SFPs that are connecting the ATTO bridge to the switch
  • B. the dark fiber cables between sites
  • C. the ATTO bridge
  • D. the SFPs in the storage controllers
  • E. the fiber cable that is connecting the ATTO bridge to the switch

Answer: ACE

NEW QUESTION 15
Click the exhibit button.
NS0-592 dumps exhibit
The storage administrator for the company example.com is attempting to join an SVM to their Active Directory as SVM1. The computer account must also be joined to the Secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit. What is the reason for this error?

  • A. The requested OU Secure does not exist in the Active Directory and must be created by the Active Directory administrator.
  • B. The requested OU Secure has incorrect principal and errored with KRB5KDC_ERR_S_PRINCIPAL_UNKNOWN.
  • C. The administrator account password used in vserver cifs create was not entered correctly.
  • D. The syntax is incorrect; it should be vserver cifs create -cifs-server svm1 -domain example.com -ou ou=Secure, dc=example, dc=com.

Answer: B

NEW QUESTION 16
......

P.S. DumpSolutions.com now are offering 100% pass ensure NS0-592 dumps! All NS0-592 exam questions have been updated with correct answers: https://www.dumpsolutions.com/NS0-592-dumps/ (65 New Questions)